Rev Mod Phys 86, 121 · 2014
Adhikari RX
Why this matters: FOUNDATIONAL GROUP REVIEW: connects interferometer response, noise budgets, isolation and conventional quantum limits.
Opt Express 32, 11751 · 2024
Venugopalan G, Salces-Cárcoba F, Arai K, Adhikari RX
Why this matters: GROUP PRIMARY METHOD: coating optimization balances reflectivity, absorption, thermal noise and fabrication tolerance.
Phys Rev D 86, 102001 · 2012
Driggers JC, Harms J, Adhikari RX
Why this matters: HISTORICAL GROUP SIMULATION: optimized sensor arrays gave broadband reductions near tenfold in modeled Newtonian noise; not a deployed observatory-wide result.
Front Artif Intell 5, 811563 · 2022
Yu H, Adhikari RX
Why this matters: GROUP PRIMARY METHOD: convolutional networks model nonlinear noise coupling; cleaning is distinct from feedback control.
Phys Rev D 105, 102002 · 2022
Richardson JW, Pandey S, Bytyqi E, Edo T, Adhikari RX
Why this matters: GROUP DESIGN STUDY: evaluates squeezed-light detector robustness to optical fabrication and installation errors.
Phys Rev A 102, 023507 · 2020
Bai Y, Venugopalan G, Kuns K, Wipf C, Markowitz A, Wade AR, Chen Y, Adhikari RX
Why this matters: GROUP PROPOSAL: phase-sensitive amplification before photodetection could mitigate readout loss; not a deployed amplifier claim.
Class Quantum Grav 37, 165003 · 2020
Adhikari RX, Aguiar O, Arai K, Barr B, Bassiri R, et al
Why this matters: GROUP-LED COLLABORATIVE DESIGN STUDY: 123 K silicon, 200 kg masses, approximately two-micron light and high arm power target improved reach; Voyager is not yet built.
Phys Rev D 109, 022009 · 2024
Michimura Y, Wang H, Salces-Carcoba F, Wipf C, Brooks A, Arai K, Adhikari RX
Why this matters: GROUP THEORETICAL ESTIMATE: crystalline-substrate and coating birefringence fluctuations introduce precision requirements.
Phys Rev D 104, 062004 · 2021
Yu H, Adhikari RX, Magee R, Sachdev S, Chen Y
Why this matters: HISTORICAL GROUP SIMULATION: neural early warnings up to 100 seconds at 40 Mpc used simulated LIGO-like data and auxiliary channels.
Phys Rev X 15, 021012 · 2025
Krenn M, Drori Y, Adhikari RX
Why this matters: GROUP COMPUTATIONAL DESIGN STUDY: Urania found 50+ simulated layouts beating an optimized Voyager baseline under modeled constraints; no built-detector claim.
Phys Rev Lett 132, 020801 · 2024
Gefen T, Tarafder R, Adhikari RX, Chen Y
Why this matters: GROUP THEORY: derives quantum precision limits and proposes triangular-cavity DFI geometry; not a new-physics detection.
Phys Rev D 98, 083019 · 2018
Hall ED, Adhikari RX, Frolov VV, Müller H, Pospelov M
Why this matters: HISTORICAL GROUP THEORY PROPOSAL: considers sensing macroscopic dark matter or a Yukawa-type force with interferometers; no detection claimed.
Phys Rev Lett 116, 061102 · 2016
Abbott BP et al
Why this matters: FOUNDATIONAL LIGO/VIRGO COLLABORATION OBSERVATION: the first binary-black-hole event establishes a historical signal, not sole-group authorship.
Phys Rev Lett 119, 141101 · 2017
Abbott BP et al
Why this matters: HISTORICAL LIGO/VIRGO COLLABORATION OBSERVATION: a third detector sharply improved sky localization for this event.
Class Quantum Grav 32, 074001 · 2015
Aasi J et al
Why this matters: FOUNDATIONAL LIGO COLLABORATION INSTRUMENT PAPER: documents the optical, suspension and isolation architecture.
Phys Rev D 111, 062002 · 2025
Capote E, Jia W, Aritomi N, et al
Why this matters: CURRENT LIGO COLLABORATION INSTRUMENT RESULT: O4 median BNS ranges 152/160 Mpc and 280–370 kW arm power are measured performance, not future design targets.
Nat Phys 7, 962 · 2011
LIGO Scientific Collaboration
Why this matters: HISTORICAL LIGO COLLABORATION INSTRUMENT RESULT: squeezing at GEO600, part of the broader field history.
Nat Photonics 7, 613 · 2013
Aasi J et al
Why this matters: HISTORICAL LIGO COLLABORATION INSTRUMENT RESULT: squeezed-light sensitivity test at Hanford, not one group’s sole invention.
Phys Rev Lett 123, 231107 · 2019
Tse M, Yu H, Kijbunchoo N, et al
Why this matters: HISTORICAL LIGO COLLABORATION RESULT: O3 sensitivity enhancement and expected event-rate gains, not guaranteed individual detections.
Nature 583, 43 · 2020
Yu H, McCuller L, Tse M, et al
Why this matters: LIGO COLLABORATION MEASUREMENT: joint light–mirror quantum uncertainty below SQL; not all detector noise below SQL.
Phys Rev X 13, 041021 · 2023
Ganapathy D, Jia W, Nakano M, Xu V, et al
Why this matters: CURRENT LIGO COLLABORATION MEASUREMENT: frequency-dependent squeezing provides broadband quantum enhancement using a 300 m filter cavity.
Class Quantum Grav 39, 025004 · 2022
Saleem M, Rana J, Gayathri V, et al
Why this matters: COLLABORATIVE SCIENCE CASE: a planned third LIGO site improves network geometry and localization; not proof of an operating site.
Science 389, 1012 · 2025
Buchli J, Tracey B, Andric T, Wipf C, Chiu YHJ, et al
Why this matters: CURRENT COLLABORATIVE HARDWARE RESULT: DeepMind–LIGO–Caltech–GSSI demonstrated one learned angular loop at Livingston, with >30x control-noise reduction in 10–30 Hz; not whole-observatory AI control.
Phys Rev Research 2, 033066 · 2020
Ormiston R, Nguyen T, Coughlin M, Adhikari RX, Katsavounidis E
Why this matters: COLLABORATIVE PRIMARY METHOD: witness-sensor neural subtraction of coupled noise from gravitational-wave data.
Mach Learn: Sci Technol 7, 055010 · 2026
Ruiz-Gonzalez C, Arlt S, Lehner S, Berzins A, Drori Y, Adhikari RX, Brandstetter J, Krenn M
Why this matters: CURRENT COLLABORATIVE COMPUTATIONAL METHOD: neural approximations of Finesse accelerate design searches; simulator fidelity still needs validation.
Nature 657, 47 · 2026
Klimesch J, Arlt S, Ruiz-Gonzalez C, et al
Why this matters: CURRENT COLLABORATIVE REVIEW: summarizes expressive search spaces, reliable simulators, computable objectives and mixed discrete/continuous search.
arXiv:2606.19649 · 2026
Maliakal S, Mann Z, Wipf C, Adhikari RX, Direkci S, Chen Y
Why this matters: CURRENT GROUP PREPRINT, NOT PEER REVIEWED: optimizes non-Gaussian sensing states under specified loss and phase-noise assumptions; not detector deployment.
arXiv:2608.19449 · 2026
Ono M, Holand NA, Bhatt R, Carney PG, Salces Càrcoba F, Arai K, Adhikari RX
Why this matters: CURRENT GROUP PREPRINT, NOT PEER REVIEWED: measured faster lock acquisition at the 40 m prototype; full-scale recovery of observing time remains conditional.
Phys Rev X 15, 011034 · 2025
Vermeulen SM, Cullen T, Grass D, MacMillan IAO, Ramirez AJ, Wack J, Korzh B, Lee VSH, Zurek KM, Stoughton C, McCuller L
Why this matters: RELATED CALTECH EXPERIMENT / DESIGN PROJECTION: McCuller, Zurek and colleagues propose GQuEST photon counting and project shorter detection times. Adhikari is not an author; no quantum-gravity signal claimed.
Phys Lett B 822, 136663 · 2021
Verlinde EP, Zurek KM
Why this matters: OUTSIDE-GROUP SPECULATIVE THEORY: gives model-dependent interferometric signatures; a proposed signal is not an established spacetime observation.
Phys Rev 83, 34 · 1951
Callen HB, Welton TA
Why this matters: FOUNDATIONAL OUTSIDE-GROUP THEORY: links energy dissipation and equilibrium fluctuations, motivating low-loss mirror materials.
Phys Rev D 23, 1693 · 1981
Caves CM
Why this matters: FOUNDATIONAL OUTSIDE-GROUP THEORY: vacuum quadratures and squeezed-state injection motivate the quantum-noise tradeoff.
Phys Rev Lett 55, 2409 · 1985
Slusher RE, Hollberg LW, Yurke B, Mertz JC, Valley JF
Why this matters: HISTORICAL OUTSIDE-GROUP MEASUREMENT: observation of squeezed states; part of a multi-group history rather than sole-group credit.